TYN33 Series Brief:
TYN Series is an intelligent multi-function solar inverter, consist of an MPPT solar Controller (high-power MPPT Controller external installation), charger, rectifier, inverter, static switch, main control circuit, and display alarm circuit, and so on. According to the user’s actual application, as you can set different mode:
PV–Gird–Battery: This series PV inverter design for photovoltaic(PV) and Grid sharing function, solar priority, photovoltaic through the MPPT controller supply to the inverter, and outputs a pure sine AC to loads, meanwhile charging the battery pack; When the solar is not enough to supply the load, it is supplemented by the grid power; utmost use solar energy and grid power, to reduce battery discharge, external battery life span.
Features:
_ Pure sine wave output
_ Built-in MPPT solar controller
_ Adopt 4 layer PCB and SMD technology
_ Can choose the AC charger by button: On-off
_ With two charging modes: AC charging mode and solar charging mode, solar charging priority.
_ Can choose two work mode: Solar-Grid-Battery, Solar –battery-Grid, Can choose it by the LCD screen
_ High-efficiency IGBT (Insulated Gate Bipolar Transistor) inverter technology: The sixth-generation low-exhaust and big-power IGBT with excellent high-speed switch feature, high voltage feature, and large current feature. Drives by electric voltage, only need small control power. The sixth-generation with lower saturation voltage, the inverter has high efficiency, low temperature, high reliability.
_ Intelligent detecting function: This system microprocessor can continually online detect power status, the breaker status, and all the working status of the circuit.
_ Excellent load feature: It is completely capable to load from 0-100% while no need to change to bypass, which makes sure the output reliable.
_ Intelligent communication-URL Based RemoteMonitoringandOperation: With RS232 and RS485 standard collocation, optional SNMP, and dry contact.
_ Perfect protection: Input/output over/low voltage protection, input surge protection, phase sequence protection, battery overcharge/discharge protection, short circuit protection, over-temperature protection, and so on, as well as an alarm function.
_ Selectable battery inspection module: Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator.
_ High-powered dynamic feature: Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only reach the high dynamic adjustment but also reduce the output voltage distortion.
Model | TYN33 10K | TYN33 20K | TYN33 30K | TYN33 40K | TYN33 50K | TYN33 60K | TYN33 80K | TYN33 100K | TYN33 120K | TYN33 160K | TYN33 200K | |
Capacity (KVA) | 10KVA | 20kVA | 30kVA | 40kVA | 50kVA | 60kVA | 80kVA | 100kVA | 120kVA | 160kVA | 200kVA | |
Power ( Watts ) | 8kW | 16kW | 24kW | 32kW | 40kW | 48kW | 64kW | 80kW | 96kW | 128kW | 160kW | |
Grid (AC Input) | Max input current (A) | 31 | 41 | 61 | 81 | 101 | 121 | 161 | 201 | 241 | 321 | 401 |
Type | Three-phase, 3L+N+G | |||||||||||
Line-Neutral Voltage | 220/230/240VAC±25% (100/110/120VAC is optional) | |||||||||||
Line-Line Voltage | 380/400/415VAC±25% (200/208/220VAC is optional) | |||||||||||
Input frequency | 50/60Hz±5% | |||||||||||
Charge voltage | 432V±1% | |||||||||||
Charge current power | capacity *20% | |||||||||||
PV | PV input range | 560VDC~800VDC | ||||||||||
Charge current | depends on inverter capacity | |||||||||||
Battery | Type | Maintenance-free lead-acid battery (other type battery need customize ) | ||||||||||
Battery voltage | 384Vdc | |||||||||||
Battery capacity | According to backup time | |||||||||||
Battery low voltage protection | >336V | |||||||||||
Inverter (Output) | Inverter output waveform | Pure sine wave, THD<3% (linear load) | ||||||||||
Line-Neutral Voltage | 220/230/240VAC±2% (100/110/120VAC is optional) | |||||||||||
Line-line Voltage | 380/400/415VAC±2% (200/208/220VAC is optional) | |||||||||||
Frequency | 50/60Hz±0.5% | |||||||||||
Dynamic feature | Inverter output transient dynamic range less than±5%,recovery time <20mS | |||||||||||
Crest factor | 3:1 | |||||||||||
Overload protection | (Inverter output)125% overload, delay 1mins protect, 150% overload, immediately protect | |||||||||||
Inverter efficiency | >90% ( 100% load ) | |||||||||||
System Parameters | Transfer time | <0.5ms ( inverter–bypass ) | ||||||||||
Protection | Output short circuit, overload, overvoltage, under-voltage, over-temperature, etc protection, have an audible and visual alarm | |||||||||||
Display | LCD display input and output voltage, output current, the inverter voltage, frequency, output current, battery voltage, PV voltage, PV charging current, temperature mode, flowcharts, current work status, event record, and system information | |||||||||||
Operating environment | Temperature 0-40℃ | |||||||||||
Relative humidity | 30%-95% | |||||||||||
Work sequence | Solar-Grid-Battery or Solar –battery-Grid, Can choose one of the modes via LCD panel | |||||||||||
Operation altitude (max) | <1000 meters ( per increase 100 meters power decrease 1%, at most 4000 meters ) | |||||||||||
Computer communicate interface | RS232/RS485 | |||||||||||
Cooling method | forced-air cooling | |||||||||||
Size W×D×H (unit: mm) | 600*620*1250 | 700*620*1530 | 980*800*1800 | 1380*950*1800 | ||||||||
Weight (kg) | 236 | 265 | 342 | 407 | 485 | 506 | 770 | 913 | 937 | 1440 | 1760 |