Product Category

UPS

CHP3000 10kVA-600kVA Three Phase Online UPS with Isolation Transformer

Product Description

Aerospace BAYKEE (Guangdong) Technology is excited
to extend our 3-phase solutions with the perfect
CHP3000 series of transformer based double
conversion online UPS. This UPS adopts high speed
microprocessor (MCU), programmable logic device
(CPLD) program which are controlled by software, the
sixth generation low exhaust and big power IGBT and
static switch as power components. This UPS combines
the world newest control spare parts and most
advanced software. It entirely breaks through the
technical bottleneck in traditional simulation age. It
adopts the digital control technology and high
precision SMD technology. This UPS can suit for various
power grid environments. All features can offer users
the big capacity, flexibility, high reliability and stability
at a value expected from BAYKEE.

Specifications

Battery Type

Battery Capacity

Battery Number

Charging Current

Temperature

Float Charging Voltage

Equalized Charging Voltage

Temperature Compensated Voltage

Charging Current

VRLA/Gel AGM Lithium-ion (Optional)

7~999Ah settable (Configure battery capacity according to backup time)

32 units 12V or 192 units 2V batteries (Nominal Voltage 384VDC)

20% System Power (Battery Capacity)

20ºC to 25ºC (For Maximum Efficiency)

432VDC

464VDC

-3mV/ºC/cell

0.1C (automatic adjust according to battery capacity

Features

  •  Advanced Communication Capabilities
    CHP3000 series has a wide range of advanced
    communications options. Standard RS232 &
    RS485, optional dry contacts or SNMP card for
    remote control.
     Excellent Load Characters
    Completely fulfill status from 0-100% without
    switching to bypass and safeguard stable output.
    Thorough Protections
    Input-Output over-low voltage protection, input
    surge protection, phase protection.
    Battery overcharge-over discharge protection,
    output overload short circuit protection.
    Overheat protection and alerting.
    High Performance Dynamic Characters
    Implement high dynamic regulation and minimize
    output voltage distortion.
     3-Phases Separately Adjustment, Balance
    Stabilizing
    Can achieve 100% unbalanced load outputs.
  • Optional EPO (Emergency Power Off)
    EPO function is designed to switch off the UPS in
    emergency conditions. The system will turn off the
    inverter, rectifier and will stop powering the load
    immediately (including the inverter and bypass)
    also the battery stops charging and discharging.
    If the input utility is still present, the UPS control
    units will remain active, however, the output will
    be turned off. To remove all power from the UPS
    the external feeder breaker should be opened.

Documents & Drawings

Main Features

 Advanced Communication Capabilities
CHP3000 series has a wide range of advanced
communications options. Standard RS232 &
RS485, optional dry contacts or SNMP card for
remote control.
 Excellent Load Characters
Completely fulfill status from 0-100% without
switching to bypass and safeguard stable output.
 Thorough Protections
Input-Output over-low voltage protection, input
surge protection, phase protection.
Battery overcharge-over discharge protection,
output overload short circuit protection.
Overheat protection and alerting.
 High Performance Dynamic Characters
Implement high dynamic regulation and minimize
output voltage distortion.
 3-Phases Separately Adjustment, Balance
Stabilizing
Can achieve 100% unbalanced load outputs.

Optional EPO (Emergency Power Off)
EPO function is designed to switch off the UPS in
emergency conditions. The system will turn off the
inverter, rectifier and will stop powering the load
immediately (including the inverter and bypass)
also the battery stops charging and discharging.
If the input utility is still present, the UPS control
units will remain active, however, the output will
be turned off. To remove all power from the UPS
the external feeder breaker should be opened.

× How can I help you?